Click here for Enquiries

You are here: Testing Charges > For Indian Customers > Testing Charges > Technical Textiles Testing [GEOTEXTILES] - Woven Geo-fabrics / Nonwoven Geo-fabrics / PVD Band Drain / Geomembrane Liner / Geo Grid / Rope Gabion / Metal Gabion

 

Sl.

No.

Tests

Minimum

Quantity

Required

Test Charges

(Rs.) per Sample

§ 

TECHNICAL TEXTILES TESTING

 

 

ü 

GEOTEXTILES

 

 

 

I. Woven Geo-fabrics

 

 

22)  

Mass per square metre [ASTM D: 5261 / ASTM D: 3776 / ISO: 9864 / IS: 14716]

1 m2

300

23)  

Tensile Strength & Elongation (Warp and Weft) [ASTM D: 5035 / IS: 1969]

1 m2

900

24)  

UV Resistance Exposure to Light Moisture & Heat in Xenon Arc Type Apparatus [ASTM D: 4355 / BS EN: 12224 / GRI: 155]

Tensile Strength (Before & After Exposure UV Xenon Arc) [ASTM D: 5035]

2 m2

80

per hour

 

 

1,800

25)  

Trapezoid Tear (Warp & Weft) [ASTM D: 4533]

1 m2

1,000

26)  

Index Puncture Resistance [ASTM D: 4833]

1 m2

1,200

27)  

Apparent Opening Size [ASTM D: 4751]

1 m2

600

28)  

Water Permeability [ASTM D: 4491 / BS: 6906–3 / IS: 14324 / ISO: 11058] 

1 m2

1,800

29)  

Grab Tensile Strength & Elongation [ASTM D: 4632]

1 m2

1,000

30)  

Mullen Bursting [ASTM D: 3786]

1 m2

350

31)  

Thickness [ASTM D: 5199]

0.5 m2

250

32)  

Cone Drop Test [EN: 918 / ISO: 13433] (Dynamic Puncture Test)

1 m2

400

33)  

Seam Strength [ASTM D: 4884 / ISO: 10321]

1 m2

1,800

34)  

Pore Size by Porometer [ASTM D: 6767]

1 m2

1,250

35)  

Abrasion Resistance [ASTM D: 4886]

Tensile Strength (Before & After by ASTM D: 5035)]

1 m2

4,000

36)  

CBR Puncture Strength [ASTM D: 6241] [ISO:12236]

1 m2

2,250

 

II. Nonwoven Geo–fabrics

 

 

37)  

Mass per square metre [ASTM D: 5261 / ISO: 9864]

1 m2

300

38)  

Wide Width Tensile Strength Machine Direction & Cross Direction

[ASTM D: 4595 / EN ISO: 10319]

1 m2

3,250

39)  

Grab Breaking Load Machine Direction & Cross Direction [ASTM D: 4632]

1 m2

1,000

40)  

Thickness [ASTM D: 5199]

0.5 m2

250

41)  

Bursting Strength [ASTM D: 3786]

1 m2

350

42)  

Index Puncture Resistance [ASTM D: 4833]

1 m2

1,200

43)  

Trapezoid Tear Strength [ASTM D: 4533]

1 m2

1,000

44)  

Cone Drop Test (Dynamic Puncture Test) [EN: 918 / ISO: 13433]

1 m2

400

45)  

Static Puncture Strength (CBR Puncture Strength) [ASTM D: 6241 / BS EN ISO: 12236]                

1 m2

2,250

46)  

Apparent Opening Size [ASTM D: 4751]

1.5 m2

600

47)  

Pore Size by Porometer [ASTM D: 6767]

0.5 m2

1,250

48)  

Water Permeability of Filter [ASTM D: 4491 / BS: 6906 / ISO: 11058] 

1 m2

1,800

49)  

Seam Strength [ASTM D: 4884 / ISO: 10321]

1 m2

1,800

50)  

Abrasion Resistance [ASTM D: 4886]

Tensile Strength (Before & After by ASTM D: 5035)]

1 m2

4,000

 

III. PVD Band Drain

 

 

51)  

Width                     

1 m

175

52)  

Weight per Linear Metre                                        

5 m

300

53)  

Tensile Strength & Elongation (Wide Width) [ASTM D: 4595]

1 m

3,250

54)  

Water Permeability of Filter [ASTM D: 4491 / BS: 6906]

1 m

1,800

55)  

Thickness of Composite [ASTM D: 5199]

1 m

250

56)  

Tensile Strength of Core [ASTM D: 4595]

1 m

3,250

57)  

Grab Strength & Elongation at Break for PVD Composite [ASTM D: 4632]

2 m

1,000

58)  

Trapezoid Tear for Filter Component only [ASTM D: 4533]

2 m

1,000

 

IVGeo-membrane Liner

 

 

59)  

Thickness [ASTM D: 5199]

0.5 m2

250

60)  

Density [ASTM D: 792]                                                

0.25 m2

500

61)  

Tensile Strength [ASTM D: 6693]

1 m2

1,200

62)  

Tear Strength [ASTM D: 1004]

1 m2

1,200

63)  

Puncture Resistance [ASTM D: 4833]

1 m2

1,200

64)  

Mass per square metre [ASTM D: 5261 / ISO: 9864]

1 m2

500

65)  

Carbon Black Content [ASTM D: 1603]

0.25 m2

1,200

66)  

Melt Flow Index [ASTM D: 1268]

0.25 m2

1,125

67)  

ESCR [ASTM D: 1693 / DIN EN: 14576]

0.25 m2

1,200

68)  

2% Secant Modulus of Polyethylene Geomembrane [ASTM D: 5323]

1 m2

1,350

 

V. Geo-Grid

 

 

69)  

Tensile Strength & Elongation

  • (Single Rib) [ASTM D: 6637 A]

3 m2

 

 

1,000

  • (Multi Rib) [ASTM D: 6637 B]

 

2,000

70)  

Carbon Black Content [ASTM D: 1603]

0.25 m2

1,200

71)  

Melt Flow Index [ASTM D: 1268]

0.25 m2

1,125

72)  

Mass per square metre [ASTM D: 5261 / ISO: 9864]

1 m2

500

73)  

Aperture Size & Number of ribs per metre

0.5 m2

300

 

VI. Rope Gabion          

 

 

74)  

Size of the Gabion

Actual

250

75)  

Thickness of Rope                                                   

1 m

250

76)  

Weight per Linear Metre

5 m

500

77)  

Tensile Strength of Rope [IS: 7071]

6 m

900

78)  

Identification of material of Rope [TGA / DSC]

0.25 m

3,500

79)  

UV Resistance Exposure to Light Moisture & Heat in Xenon Arc Type Apparatus [ASTM D: 4355 / BS EN: 12224 / GRI: 155]

Tensile Strength (Before & After Exposure UV Xenon Arc) [IS:7071]

8 m

80

 per hour

 

 

1,800

80)  

Tensile Strength of Rope after Thermal Treatment (Heating)

6 m

1,200

 

VII. Metal Gabion   [ASTM D: 975]       

 

 

81)  

Size of the Gabion

 

250

82)  

Thickness of Wire                                                

 

250

83)  

Tensile Strength of Wire

 

1,200